TY - CONF ID - SisLab3840 UR - http://dx.doi.org/10.1109/MEMSYS.2019.8870761 A1 - Tran, Van Ngoc A1 - Bui, Thanh Tung A1 - Tran, Canh-Dung A1 - Dinh, Thien Xuan A1 - Phan, Hoa Thanh A1 - Van, Dong Pham A1 - Chu, Duc Trinh A1 - Dau, Thanh Van Y1 - 2019/01// N2 - We present for the first time a novel gyroscope using circulatory electro-hydrodynamics flow in a confined space. Three point-ring corona actuator is to generate ionic flows in three separated channels and the ionic flows then merge together at a nozzle of the main chamber to create a jet flow. The residual charge of ion winds is removed by a master-ring electrode. By the effect of angular rate, the jet flow handled by a hotwire anemometry is deflected and sensed. Results by both experiment and numerical simulation consistently show good repeatability and stability of the new configuration-based device. Since ion wind is generated by a minimum power, the device does not require any vibrating component, thus the device is robust, low cost and energy consumption. TI - Study on Point-to-Ring Corona Based Gyroscope SP - 672 M2 - Seoul, Korea AV - none EP - 675 T2 - 2019 IEEE 32nd International Conference on Micro Electro Mechanical Systems (MEMS) ER -